products_banner

Products

  • EMT connectors,set screw   – steel

    EMT connectors,set screw – steel

    1. Application:  These uninsulated electrical connectors are used in dry locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Uninsulated, steel set-screw connectors provide concretetight connections when taped and properly secured with the included locknut. They are rated for electrical applications above 600 volts. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junct...
  • EMT connectors, set screw insulated  – steel

    EMT connectors, set screw insulated – steel

    1. Application:  These insulated electrical connectors are used in dry locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Insulated, steel set-screw connectors provide concrete-tight connections when taped and properly secured with the included locknut. They are rated for electrical applications above 600 volts. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction...
  • EMT couplings,set screw  – steel

    EMT couplings,set screw – steel

    1. Application:  These electrical couplings are used in dry locations to connect the ends of two EMT thinwall conduits together to extend the raceway. Steel, setscrew couplings provide concrete-tight connections when taped and properly secured with the included set-screws. These steel set-screw couplings are rated for electrical applications above 600 volts. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Set-screw c...
  • EMT compression connectors -raintight – steel

    EMT compression connectors -raintight – steel

    1. Application: These rain-tight compression connectors are used in wet locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Rain-tight EMT compression connectors have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements. 2. Advantages:Heavy-gauge construction maintains mechanical protection and solid grounding of the conduit to designated electrical junction boxes or enclosures. Compression co...
  • EMT compression connectors -raintight – insulated

    EMT compression connectors -raintight – insulated

    1. Application: These rain-tight compression connectors are used in wet locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Rain-tight EMT compression connectors have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements. 2. Advantages:Heavy-gauge construction maintains mechanical protection and solid grounding of the conduit to designated electrical junction boxes or enclosures. Compression co...
  • EMT compression couplings -raintight

    EMT compression couplings -raintight

    1. Application: These rain-tight compression couplings are used in wet locations to connect the ends of two EMT thinwall conduits together to extend the raceway. Rain-tight steel EMT compression couplings have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Compression couplings are zinc electropl...
  • Rigid couplings

    Rigid couplings

    1. Application: These threaded couplings are used to join two ends of threaded rigid conduits or IMC conduits together. They can also be used with chase nipples and connectors to bond threaded conduits to electrical junction boxes or enclosures. 2. Advantages:Versatile threaded design works with all standard threaded connectors. These couplings are often used as a component to convert flexible metal conduits to EMT thinwall, rigid conduit or liquid-tight conduits by using the related threade...
  • Hammer-on beam flange clip
  • Hammer-on beam flange clamp

    Hammer-on beam flange clamp

    1. Application: These hammer-on beam clamps are used to suspend boxes, fixtures and bridle rings to beam flanges. 2. Advantages:Quick, hammer-on design eliminates the hardware costs and installation hours associated with traditional beam clamps. 3. Field Names: Multi purpose clamp, hammer on beam clamp, bang on beam clamp, multi purpose clip. 4. Material: Spring Steel Black
  • Spring -steel beam clamp- light duty

    Spring -steel beam clamp- light duty

    1. Application: These steel beam clamps are used to support light-duty loads from structural beams. 2. Advantages:Beam clamps have an easy and fast installation and fit beam flanges up to 3/4″.Additionally, they have sharp teeth that bite into beam surfaces to protect against slippage. 3. Field Names: Light duty beam clamp, spring steel clamp. 4. Material: Steel, Black
  • Push -in conduit hangers
  • Snap-lock conduit hangers

    Snap-lock conduit hangers

    1. Application: These spring steel conduit hangers are used to install conduit with a beam clamp. They can be installed both horizontally and vertically. These conduit hangers can support 3/8”to 2”conduit runs. 2. Advantages:Spring steel conduit hangers eliminate the need for additional fasteners. Their spring steel plated construction makes them durable and secure. 3. Field Names: Spring steel conduit hangers, black conduit hangers, black minnies, spring steel minnies, squeeze type conduit ...