Fittings

  • EMT connectors, set screw insulated  – steel

    EMT connectors, set screw insulated – steel

    1. Application:  These insulated electrical connectors are used in dry locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Insulated, steel set-screw connectors provide concrete-tight connections when taped and properly secured with the included locknut. They are rated for electrical applications above 600 volts. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction...
  • EMT couplings,set screw  – steel

    EMT couplings,set screw – steel

    1. Application:  These electrical couplings are used in dry locations to connect the ends of two EMT thinwall conduits together to extend the raceway. Steel, setscrew couplings provide concrete-tight connections when taped and properly secured with the included set-screws. These steel set-screw couplings are rated for electrical applications above 600 volts. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Set-screw c...
  • EMT compression connectors -raintight – steel

    EMT compression connectors -raintight – steel

    1. Application: These rain-tight compression connectors are used in wet locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Rain-tight EMT compression connectors have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements. 2. Advantages:Heavy-gauge construction maintains mechanical protection and solid grounding of the conduit to designated electrical junction boxes or enclosures. Compression co...
  • EMT compression connectors -raintight – insulated

    EMT compression connectors -raintight – insulated

    1. Application: These rain-tight compression connectors are used in wet locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Rain-tight EMT compression connectors have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements. 2. Advantages:Heavy-gauge construction maintains mechanical protection and solid grounding of the conduit to designated electrical junction boxes or enclosures. Compression co...
  • EMT compression couplings -raintight

    EMT compression couplings -raintight

    1. Application: These rain-tight compression couplings are used in wet locations to connect the ends of two EMT thinwall conduits together to extend the raceway. Rain-tight steel EMT compression couplings have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Compression couplings are zinc electropl...
  • Rigid couplings

    Rigid couplings

    1. Application: These threaded couplings are used to join two ends of threaded rigid conduits or IMC conduits together. They can also be used with chase nipples and connectors to bond threaded conduits to electrical junction boxes or enclosures. 2. Advantages:Versatile threaded design works with all standard threaded connectors. These couplings are often used as a component to convert flexible metal conduits to EMT thinwall, rigid conduit or liquid-tight conduits by using the related threade...
  • Cone nuts
  • Spring nuts

    Spring nuts

    1. Application: These spring nuts are inserted inside strut channel to accept 1/4”,3/8”or 1/2”threaded fasteners or bolts. 2. Advantages:Spring nuts provide a quick and easy way to hang or mount multiple products from a single strut channel. 3. Field Names: Spring Nuts, strut nuts, boingie nuts. 4. Material: Zinc Plated Steel
  • Steel locknut

    Steel locknut

    1. Application: These heavy-duty locknuts are used in dry locations to secure threaded conduits or connectors to electrical junction boxes or enclosures. 2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. Heavy-duty locknuts are zinc electroplated for excellent corrosion protection in damp locations. Serrated teeth on the locknut bite into the box and enclosure to prevent vibr...
  • Threaded grounding bushing -insulated -malleable iron

    Threaded grounding bushing -insulated -malleable iron

    1. Application: These threaded grounding bushings are used to provide a means of grounding rigid or IMC conduits. 2. Advantages:Lay-in lug style threaded grounding bushings make it easy to insert a grounding wire. They feature dual-rated aluminum grounding lugs that may be used with both copper and aluminum grounding conductors. Their insuliner temperature is rated at 150°C and their construction ensures mechanical protection for the raceway. Threaded grounding bushings are zinc electroplate...
  • Corner angle
  • Quick shot threaded hanger clips